12V 140A Voltage Sensitive Relay

For delivery on ..., order this item ...
  • Type: Voltage Sensitive Relay
  • Voltage: 12V
  • Continuous Rating : 12VDC/140 amps
  • Engage Voltage: 13.7VDC
  • Disengage Voltage: 12.8VDC
  • Ignition Protected: UL1107
  • Stud: M6
  • Ground: Negative, 0.5M/18 AWG wire
  • Quantity: 1
  • Automatic discounts when ordering 10+ relays
SKU: GTSE-ERELAY-41
27.8 33.36

Bulk Discount Save up to %

Number of Packs Price Per Pack Excl. VAT You Save
1+ £27.80 -
10 + £25.96 ...


Excl. VAT: £ 27.8
Incl. VAT: £ 33.36

Subtotal:

Excl. VAT
Incl. VAT
Unlock 30-day payment terms
Unlock 30-day payment terms

Business customers can apply for a 30-day EOM Credit Account. No fees. No Interest. Fast Approval

Create Account
This device lets you charge two separate battery banks from one source, like a vehicle alternator, without draining the main battery. The voltage-sensitive relay (VSR) senses the main battery voltage and only connects the secondary bank when the primary is fully charged, ensuring the secondary bank never drains the main.
 
With dual-sense capability, the VSR detects voltage in both batteries. If either battery is charging, it activates, allowing for charging from an external source too. It handles up to 140A with zero voltage drop, and its no-moving-parts design makes it ideal for marine applications and vehicle split charging. This is a direct alternative to the Durite 140A VSR and comes with E Mark approval.
 
Fitting Instructions
Connect the main and auxiliary batteries to the terminals labelled 'Start Bat' and 'Second Bat.' The small black wire should be connected to earth.
 
Technical Information
Continuous Rating: 12VDC/140A
Sense: Dual
Engage Voltage: 13.7VDC
Disengage Voltage: 12.8VDC
Ignition Protected: UL1107
Stud: M6
Ground: Negative, 0.5M/18 AWG wire
Weight: 0.2Kg
Dimensions: 68mm x 68mm x 49mm
Mounting Screws: 4.8 x 50mm and 3.5 x 13mm